Life Of The Parts - Furuno TZT9 Operator's Manual

Multifunction display
Hide thumbs Also See for TZT9:
Table of Contents

Advertisement

14. MAINTENANCE, TROUBLESHOOTING
Check item
Radar antenna Dirt on the radar antenna
14.2

Life of the Parts

Fuse replacement
The TZT has a fuse that protects the TZT from high electric current and equipment
fault. If you cannot turn on the power, check the fuse to see if it has blown. Find the
reason for the blown fuse before you replace the fuse. If the fuse blows again after the
replacement, contact your dealer for information. A wrong fuse can damage the equip-
ment.
Name
Fuse
Fuse
Fuse
Fuse
Lithium battery replacement
The lithium battery on the Main board in this equipment keeps the time data of the in-
ternal clock alive when the power is turned off. The life of the battery is approximately
three years (in power-off). When the voltage of the battery is low, the message re-
questing replacement appears at the top of the screen. When this occurs, contact your
dealer about replacement of the battery.
Note: Dispose of the battery in accordance with local regulations.
Part
Lithium battery
14-2
Check point
can reduce the sensitivity.
Use the proper fuse.
A wrong fuse can damage the equipment
and cause fire.
Type
FGBO-A 125V 4A PBF
FGBO 125V 7A PBF
FGBO-A 125V 5A PBF
FGBO 125V 10A PBF
Use the proper lithium battery.
A wrong lithium battery may burst.
Type
CR2032H
Clean the radiator (or radome) with a
cloth wetted with freshwater. Do not use
commercial cleaners to clean the radia-
tor. Those cleaners can remove paint
and markings.
WARNING
Code No.
000-155-851-10
000-155-831-10
000-155-853-10
000-155-826-10
CAUTION
Code No.
-
Remedy
Remarks
For TZT9/TZTBB, 24 VDC
For TZT9, 12 VDC
For TZT14, 24 VDC
For TZT14/TZTBB, 12 VDC
Remarks
Use of Japanese make bat-
tery is recommended.

Advertisement