Itb Cleaning Unit; Removing The Right Cover (Upper) - Canon iR C6800 Series Service Manual

Hide thumbs Also See for iR C6800 Series:
Table of Contents

Advertisement

3) While pushing the 2 hooks [1] frond on both sides
of the fixing/feeding assembly, slide out the fixing/
feeding assembly [2] fully.
[1]
F-7-716
4) Remove the screw [1], and detach the connector
cover [2].
[1]
F-7-717
5) Disconnect the connector [1].
[1]
F-7-718
[2]
[1]
[2]
6) Remove the 2 stepped screws [1].
[1]
F-7-719
7) While shifting the secondary transfer unit [1],
disconnect the 2 connectors [2]; then, detach the
secondary transfer unit.
[1]
F-7-720

7.11.25 ITB Cleaning Unit

7.11.25.1 Removing the Right
Cover (upper)
1) Remove the 2 screws [1], and detach the right cover
(upper) [2].
[1]
F-7-721
Chapter 7
[2]
0003-8260
[2]
7-203