Cisco Nexus 5500 Series NX-OS Configuration Manual page 102

Nx-os san
Table of Contents

Advertisement

Configuration Examples for FCoE NPV
switch(config-sys-qos)# service-policy type queuing output fcoe-default-out-policy
switch(config-sys-qos)# service-policy type network-qos fcoe-default-nq-policy
switch(config)# vsan database
switch(config-vsan-db)# vsan 50-51
switch(config-vsan-db)# vlan 50
switch(config-vlan)# fcoe vsan 50
switch(config-vlan)# vlan 51
switch(config-vlan)# fcoe vsan 51
This example shows a summary of the interface configuration information for trunked NP
ports:
switch# show interface brief | grep TNP
fc2/5
fc2/6
vfc130
switch#
This example shows the running configuration information about FCoE:
switch# show running-config fcoe_mgr
!Command: show running-config fcoe_mgr
!Time: Wed Jan
version 6.0(2)N1(1)
interface vfc1
bind interface Ethernet1/19
interface vfc2
bind interface Ethernet1/2
interface vfc90
bind interface Ethernet1/9
interface vfc100
bind interface Ethernet1/10
interface vfc110
bind interface port-channel110
interface vfc111
bind interface Ethernet1/11
interface vfc120
bind interface port-channel120
interface vfc130
bind interface port-channel130
interface vfc177
bind interface Ethernet1/7
fcoe fka-adv-period 16
This example shows the FCoE VLAN to VSAN mappings:
switch# show vlan fcoe
Original VLAN ID
----------------
400
20
100
500
200
300
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x
78
400
NP
on
trunking
400
NP
on
trunking
1
NP
on
trunking
20 21:59:39 2013
Translated VSAN ID
------------------
400
20
100
500
200
300
swl
TNP
2
--
swl
TNP
2
--
--
TNP
auto --
Association State
-----------------
Operational
Operational
Operational
Operational
Operational
Operational
Configuring FCoE NPV
OL-30895-01

Advertisement

Table of Contents
loading

Table of Contents