User Access Control Configuration

Command: /cfg/sys/user
[User Access Control Menu]
This menu allows you to set passwords and display current user statistics. Passwords can be a
maximum of 15 characters. To disable a user, set the password to null by simply pressing the
Enter key when prompted for the password.
The following table describes the User Access Control Configuration Menu options.
Table 6-7: User Access Control Configuration Menu Options
Command
usrpw
opw
admpw
cur
HP ProLiant BL p-Class GbE2 Interconnect Switch Command Reference Guide
HP CONFIDENTIAL Codename: Strawberry Part Number: 331404-001 Last Saved On: 7/17/03 12:57 PM
usrpw
- Set user password (user)
opw
- Set operator password (oper)
admpw
- Set administrator password (admin)
cur
- Display current user statistics
Description
Sets the user (user) password. The user has no direct responsibility for GbE2
Interconnect Switch management. The user can view GbE2 Interconnect
Switch status information and statistics, but cannot make any configuration
changes.
Sets the operator (oper) password. The operator manages all functions of the
GbE2 Interconnect Switch. The operator can view all GbE2 Interconnect
Switch information and statistics and can reset ports. The operator account is
disabled by default.
Sets the administrator (admin) password. The super user administrator has
complete access to all menus, information, and configuration commands on
the GbE2 Interconnect Switch, including the ability to change both the user
and administrator passwords.
Displays the current user status.
The Configuration Menu