Service Procedure - Integra DTR-7.7 Service Manual

Hide thumbs Also See for DTR-7.7:
Table of Contents

Advertisement

QQ
3 7 63 1515 0

SERVICE PROCEDURE

1. Replacing the fuses
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse, For fuse rating, refer to
the marking adjacent to the symbol.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
<Notes>
<DD> : DTR-7.7 U.S.A. model
: DTR-7.7 Australian model
<PA>
REF NO.
F901
F901
F903
F903
F931
F932
F951
F952
F6901
TE
L 13942296513
F6902
2. To initialize the unit
1. Press and hold down VIDEO 1 button, then press STANDBY/ON button when the unit is Power on.
2. After " C l ear " is displayed, the preset memory and each mode stored in the memory are initialized and will
return to the factory settings, and turn to Standby mode.
3. Safety check out
(U.S.A. model only)
After correcting the original service problem, perform the following safety check before releasing the unit to
the customer.
Leakage current Check
Measure the leakage current to a known earth ground (water pipe or conduct etc.) by connecting a leakage current
tester between the earth ground and exposed metal parts of the unit (input/output ground terminals, screw heads or
metal overlays etc.).
Plug the power supply cord directly into a 120Vac 60Hz wall socket and turn STANDBY button on.
Any current measured must not exceed 0.5mA.
4. Memory Backup
This model uses a battery-less memory backup system in order to retain radio presets and other settings
when it's unplugged or in the case of a power failure.
Although no batteries are required, the unit must be plugged into an AC outlet in order to charge the
backup system. Once it has been charged, the unit will retain the settings for several weeks,
although this depends on the environment and will be shorter in humid climates.
www
.
http://www.xiaoyu163.com
This symbol located near the fuse indicates that the
Ce symbole indique que le fusible utilise est e lent.
PART NAME
DESCRIPTION
FUSE
10A-UL/T-233
FUSE
6.3A-SE-EAK
FUSE
5A-UL/T-233
FUSE
2.5A-SE-EAK
FUSE
1.6A-SE-EAK
FUSE
1.6A-SE-EAK
FUSE
6.3A-SE-EAK
FUSE
6.3A-SE-EAK
FUSE
12A-TUL-250V
FUSE
12A-TUL-250V
x
ao
y
i
http://www.xiaoyu163.com
8
PART NO.
REMARKS
252330GR
!, <DD>
252079GR
!, <PA>
252326GR
!, <DD>
!, <PA>
252075GR
252073GR
!
252073GR
!
252079GR
!
252079GR
!
252301GR
!
Q Q
3
6 7
1 3
252301GR
!
.
u163
.
2 9
9 4
2 8
1 5
0 5
8
2 9
9 4
m
co
DTR-7.7
9 9
2 8
9 9

Advertisement

Table of Contents
loading

Table of Contents