2-4 Using the Analyzer
Now try to delete the trigger level. Notice that the following level is
made the trigger level until it is the second to last; then, the previous
level is made the trigger level.

Storage Qualifier Field

The storage qualifier field allows you to specify which states are stored
while the analyzer searches for that sequence level's find or trigger
state.
Move the cursor to a storage qualifier field and use the Tab key to
scroll through the choices. You will see the following options:
any state
All states are stored.
no state
No states are stored.
r, !r
Only states in the range (r) or states not in the range
(!r) are stored. Ranges are defined in the patterns
and expressions screen described below.
a, b, c, d,
Only states that match the pattern are stored. Up to
e, f, g, h
eight different patterns can be defined. Patterns are
defined in the patterns and expressions screen
described below.
arm
Store only the state executing when the analyzer is
armed (enabled) by some condition external to the
analyzer. Conditions that can be used to arm the
analyzer are described in the "Making Coordinated
Measurements" chapter.
These same options are available in any state qualifier field.

Find State or Trigger on State Field

The "find state" or "trigger on" state field allows you to define the state
that causes the analyzer to start searching for the following sequence
level or that causes the analyzer to trigger.
The options available in this field are the same as for the storage
qualifier field.