Further Actions In Step 7/Ncm Pc; Bios Description; Overview - Siemens SIMATIC IPC627D Operating Instructions Manual

Industrial pc
Hide thumbs Also See for SIMATIC IPC627D:
Table of Contents

Advertisement

8.5.5.4

Further actions in STEP 7/NCM PC

Configuring
Your PC is now ready, although you still have to configure the SIMATIC NET communication
software. The rest of the procedure is described in the "Commissioning PC Stations" manual
(on the Windows PC that also contains STEP 7/NCM PC: Start > Simatic > Documentation >
English > Commissioning PC Stations).
8.6

BIOS description

8.6.1

Overview

BIOS Setup program
The BIOS Setup program, or BIOS Setup for short, is located, together with the setup
parameters, in a FLASH block on the motherboard.
You change the setup parameters of the device in the BIOS Setup. Examples: System time,
hard disks or boot order.
Changing the device configuration
Your device configuration is preset for operating with the included software. You should only
change the default setup parameters if you have made technical changes to your device, or
if a fault occurs when the device is switched on.
NOTICE
Malfunctions can occur with running software CPU
If a BIOS update of the PC is performed while SIMATIC software controller, a SIMATIC
WinAC for example, is running, the software CPU can malfunction, resulting in
communication interruptions or failures, for example. Other actions that put a heavy load on
the PC hardware, for example, running hardware tests such as benchmarks, can result in
malfunctions of the software CPU.
Do not run a BIOS update or other actions that would put a heavy load on the hardware
during operation of a software CPU.
Switch the software CPU to "STOP" before you run a BIOS update or perform other critical
actions.
SIMATIC IPC627D/827D
Operating Instructions, 09/2014, A5E32990859-AB
Technical specifications
8.6 BIOS description
147

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ipc827d

Table of Contents