Technical Specifications - Lincoln Electric SPEEDTEC 400S Operator's Manual

Hide thumbs Also See for SPEEDTEC 400S:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.
EMC classification of this product is class A in accordance with electromagnetic compatibility standard EN 60974-10 and
therefore the product is designed to be used in an industrial environment only.
The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system.
locations, due to conducted as well as radiated disturbances.

Technical Specifications

Input Voltage
400 V ± 10%
Three Phase
(Based on a 10 min. period)
SMAW
400S:
GTAW-DC
GMAW
SMAW
500S:
GTAW-DC
GMAW
Welding Current Range
SMAW
400S:
GTAW-DC
GMAW
SMAW
500S:
GTAW-DC
GMAW
Fuse or Circuit Breaker Size
400S:
25 A, Z curve recommended
500S:
40 A, Z curve recommended
Height
400S:
476 mm
500S:
Operating Temperature
-10°C to +40°C
English
There may be potential difficulties in ensuring electromagnetic compatibility in those
Input Power at Rated Output
SMAW
400S:
GTAW-DC
GMAW
SMAW
500S:
GTAW-DC
GMAW
RATED OUTPUT AT 40°C
Duty Cycle
80%
100%
80%
100%
80%
100%
40%
100%
40%
100%
40%
100%
5 A – 400 A
5 A – 400 A
20 A – 400 A
5 A – 500 A
5 A – 500 A
20 A – 500 A
RECOMMENDED INPUT CABLE AND FUSE SIZES
PHYSICAL DIMENSIONS
Width
305 mm
WARNING
WARNING
INPUT
17.1 kVA @ 80% duty cycle
12.8 kVA @ 80% duty cycle
16.2 kVA @ 80% duty cycle
24.0 kVA @ 40% duty cycle
18.4 kVA @ 40% duty cycle
23.3 kVA @ 40% duty cycle
Output Current
400 A
390 A
400 A
390 A
400 A
390 A
500 A
390 A
500 A
390 A
500 A
390 A
OUTPUT RANGE
Maximum Open Circuit Voltage
400S:
500S:
400S:
500S:
Length
600 mm
5
Frequency
Output Voltage
36.0 Vdc
35.5 Vdc
26.0 Vdc
25.5 Vdc
34.0 Vdc
33.5 Vdc
40.0 Vdc
35.5 Vdc
30.0 Vdc
25.5 Vdc
39.0 Vdc
33.5 Vdc
73 Vdc
Input Power Cable
2
4 x 4 mm
Weight
50 kg
Storage Temperature
-25°C to +55°C
50/60 Hz