Mitsubishi QJ71C24N User Manual page 33

Melsec-q series
Hide thumbs Also See for QJ71C24N:
Table of Contents

Advertisement

1 OVERVIEW
QJ71E71
Q25HCPU
MELSEC
RUN
POWER
MODE
INIT.
RUN
OPEN
SD
ERR.
10BASE-T
USER
BAT.
BOOT
10BASE
PULL
USB
RS-232
+12V
12G
MITSUBISHI
QJ71E71
MELSEC
Q25HCPU
RUN
POWER
MODE
INIT.
RUN
OPEN
SD
ERR.
10BASE-T
USER
BAT.
BOOT
10BASE
PULL
USB
RS-232
+12V
12G
MITSUBISHI
QJ71E71
Q25HCPU
RUN
MODE
INIT.
RUN
OPEN
ERR.
USER
BAT.
BOOT
10BASE
PULL
USB
RS-232
MITSUBISHI
1 - 7
(5) Monitoring the programmable controller CPU
(a) The self-station's programmable controller CPU can be monitored at time
intervals set by the user without using a sequence program.
1) The following monitoring information can be sent/notified as the result of
monitoring the programmable controller CPU.
• Transmission of information on devices and the programmable
controller CPU status to be monitored. (It is also possible to send the
monitoring information through combined use of the modem function.)
• Notification of a notification message (string data) registered as the
connection data of the modem function, through combined use of the
modem function.
2) The user can select either one of the following timing choices at which to
send the programmable controller CPU monitoring result to the external
device.
• Send/notify every time the programmable controller CPU is
monitored (periodic transmission).
• Send/notify when the information read from the programmable
controller CPU matches the conditions set by the user (conditional
transmission).
(b) The programmable controller CPU monitoring function can be used in
communication using the MC or non procedure protocol.
QJ71C24
ERR.
COM.ERR
CH1.
CH2.
RD
CH1.
RS-232
CH.2
SDA
1
SG
2
SDB
(FG)
3
RDA
4
(FG)
5
RDB
6
RS-422
7
/485
QJ71C24
ERR.
COM.ERR
CH1.
CH2.
RD
CH1.
RS-232
Modem
CH.2
SDA
1
SG
2
SDB
(FG)
3
RDA
4
(FG)
5
RDB
6
RS-422
7
/485
(6) Remote communications using the modem function
(a) Data communication can be performed with a remotely located external device.
(b) Modem initialization and line connection/disconnection can be performed.
(c) Data communication can be performed using the MC, non procedure or
bidirectional protocol.
QJ71C24
ERR.
COM.ERR
CH1.
CH2.
SD
RD
CH1.
10BASE-T
Modem
RS-232
CH.2
SDA
1
SG
2
SDB
(FG)
3
RDA
4
(FG)
5
RDB
+12V
6
12G
RS-422
7
/485
(7) Initial settings and communication settings without using a
sequence program
Various initial settings can be performed using the GX Configurator-SC
(SW0D5C-QSCU-E or later).
(Details are explained in the User's Manual (Application).)
Data
Notification
message
(Details are explained in the User's Manual (Application).)
MELSEC-Q
Pager
Modem
1 - 7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2

Table of Contents