Diagnosis test

To start the key position calibration:
If the function keys seem out of alignment, calibrate the
key position as follows.
q
z While pressing the needle up/down and lock stitch
buttons, turn the power switch on.
The LCD screens display "----".
x Press the auto-lock button button q to enter the key
position calibration.
(t3)
t
(t4)
y
c The key position adjustment screen appears and
"t1" is shown on the right side of the screen. With the
touch panel stylus w, press e on the touch panel of
your machine.
v "t2" will be shown on the LCD screen. Press r on the
touch panel.
b "t3" will be shown on the LCD screen. Press t on the
touch panel.
n "t4" will be shown on the LCD screen. Press y on the
touch panel.
m "t5" will be shown on the LCD screen. Press u on the
touch panel.
, The screen will be back to the "----".