Needle plate release lever
Needle plate
Pin
Free arm cover
Hooks
Changing external parts
Hook B
Setscrew
Hook A
Tabs
Free arm cover
Free arm cover
To remove:
1. Remove the machine base and base cover (see page 3).
Press the needle plate release lever to remove the
needle plate.
2. Remove the pin.
Loosen the setscrew.
3. Unlock the hook A (inside of the machine base) and B
(edge of the free arm).
4. Slide the free arm cover to the left.
Remove the free arm cover while removing the 3
hooks and 2 tabs from the free arm.
To attach:
1. Follow the above procedure in reverse.
4