5-3. ERROR CODES

If an error code occurs, retry the communication. If the same problem occurs, try to fix the problem as suggested
below. Note that error codes 4-00, 01, 02, and 10 only appear in the error code display and on the service report.
Code
Meaning
0-00
DIS/NSF not detected within 40 s
of Start being pressed
0-01
DCN received unexpectedly
0-03
Incompatible modem at other end The other terminal is incompatible.
0-04
CFR or FTT not received after
modem training
0-05
Unsuccessful after modem
training at 2400 bps
0-06
The other terminal did not reply to
DCS
0-07
No post-message response from
the other end after a page was
sent (3rd try failed)
0-08
The other end sent RTN or PIN
after receiving a page, because
there were too many errors
Suggested Cause/Action
Check the line connection.
Check the LIU - FDU - FCE connectors.
The machine at other end may be incompatible.
Replace the FDU or LIU.
Check for DIS/NSF with an oscilloscope.
If the rx signal is weak, there may be a bad line.
The other party is out of paper or has a jammed printer.
The other party pressed Stop during communication.
Check the line connection.
Check the LIU - FDU -FCE connectors.
Try changing the tx level (use NCU parameter 10).
Replace the FCE, FDU or LIU.
The other terminal may be faulty; try sending to another machine.
If the rx signal is weak or defective, there may be a bad line.
Check the line connection.
Check the FCE - LIU - FDU connectors.
Try adjusting the tx level (use NCU parameter 10).
Replace the FCE, FDU or LIU.
Check for line problems.
Check the line connection.
Check the FCE - FDU - LIU connectors.
Try adjusting the tx level (use NCU parameter 10).
Replace the FCE, LIU or FDU.
The other end may be defective or incompatible; try sending to
another machine.
Check for line problems.
Check the line connection.
Check the FCE - FDU - LIU connectors.
Replace the FCE, LIU or FDU.
The other end may have jammed or run out of paper.
The other end user may have disconnected the call.
Check for a bad line.
The other end may be defective; try sending to another machine.
Check the line connection.
Check the FCE - FDU - LIU connectors.
Replace the FCE, LIU or FDU.
The other end may have jammed, or run out of paper or memory
space.
Try adjusting the tx level (use NCU parameter 10).
The other end may have a defective modem/NCU/FCU; try sending
to another machine.
Check for line problems and noise.
5-6