Portable Air Compressor
Operation
(Continued)
from tank by opening the drain valve
Moisture in compressed air will form into droplets as it comes from an air
located underneath the tank.
compressor pump. When humidity is high or when a compressor is in continuous
LUBRICATION
use for an extended period of time, this moisture will collect in the tank. When
using a paint spray or sandblast gun, this water will be carried from the tank
This is an oilless product and DOES
NOT require lubrication to operate.
through the hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially
BEFORE FIRST START-UP
when spraying other than water based paints. If sandblasting, it will cause the
sand to cake and clog the gun, rendering it ineffective. A filter in the air line
BREAK-IN PROCEDURE
(MP3105), located as near to the gun as possible, will help eliminate this
(Complete this procedure before using
moisture.
compressor for the first time. Once
completed, it is not necessary to
If the compressor is left in the ON
repeat.)
position and air is depleted from the
1. Turn regulator knob fully clockwise
tank by use of a tire chuck, tool, etc.,
(to the right) to open air flow.
the compressor will restart
automatically at its preset "cut-in"
2. Turn on/off switch to OFF position.
pressure. When a tool is being used
3. Plug in power cord.
continuously, the compressor will cycle
on and off automatically.
4. Turn on/off switch to ON position
In the OFF position, the pressure switch
and run compressor for 5 minutes.
cannot function and the compressor
5. Turn on/off switch to OFF position.
will not operate. Make sure switch is in
OFF position when connecting or
6. Unplug power cord.
disconnecting power cord from
The compressor is now ready for use.
electrical outlet.
BEFORE EACH START-UP
ASME SAFETY VALVE
OPERATING PROCEDURE
WARNING
!
1. Turn regulator knob fully
the safety valve!
counterclockwise (to the left) to close
air flow.
Check the safety valve by performing
the following steps:
2. Connect air hose to outlet of
1. Plug the compressor in and run until
regulator.
shut off pressure is reached (see
3. Turn on/off switch to OFF position.
Operating Procedure).
2. Wearing safety glasses, pull the ring
4. Plug in power cord.
on the safety valve to release
5. Turn on/off switch to ON position
pressure from compressor tank. Use
and let compressor run until it
your other hand to deflect fast-
reaches automatic shutoff pressure.
moving air from being directed
toward your face. See Figure 3.
6. Attach tire chuck or tool to end of
hose.
7. Turn regulator knob clockwise (to
the right) to desired pressure of tool
being used.
On/Off cycling of compressor
In the ON position, the compressor
pumps air into the tank. When a shut-
off (preset "cut-out") pressure is
reached, the compressor automatically
Figure 3
shuts off.
www.chpower.com
MOISTURE IN COMPRESSED AIR
3. The safety valve should
automatically close at approximately
40-50 psi. If the safety valve does not
allow air to be released when you
pull on the ring, or if it does not
close automatically, it MUST be
replaced.
REGULATOR KNOB
1. This knob controls air pressure to an
air operated tool or tire chuck.
2. Turn knob clockwise to increase air
pressure.
3. To lower air pressure turn knob
counterclockwise.
4. Turn fully counterclockwise to shut
Do not remove or
off flow of air completely.
attempt to adjust

Maintenance

WARNING
!
Disconnect power
source then release all
pressure from the
system before
attempting to install,
service, relocate or perform any
maintenance.
Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is
used.
Safety valve must
WARNING
!
be replaced if it
cannot be actuated or it leaks air after
ring is released.
1. Turn compressor off and release
pressure from system. (To release
pressure from system, pull ring on
ASME safety valve. Deflect escaping
air by shielding valve with one hand
4
Guía de diagnóstico de averías
Problema
Posible(s) Causa(s)
El compresor no funciona
1. El interruptor está en la posición OFF
(apagado)
2. No hay corriente eléctrica en el
tomacorriente de la pared
3. El compresor alcanzó la presión de corte
automático
4. Motor recalentado
5. Interruptor de presión defectuoso
El protector térmico de
1. Falta de ventilación adecuada/
sobrecarga detiene el
temperatura ambiente demasiado alta
funcionamiento
2. Fallaron las válvulas del compresor
reiteradamente
Golpeteos, zumbidos,
1. El tanque no está nivelado
vibración excesiva.
2. Cojinete defectuoso en la excéntrica o en
el eje del motor
3. El aro del cilindro o pistón está desgastado
o marcado
1. Válvula de drenaje floja
La presión del tanque
disminuye cuando se
2. Fugas en la válvula de retención
apaga el compresor
3. Conexiones flojas (accesorios, tubería, etc.)
El compresor funciona en
1. Uso excesivo de aire, el compresor es
forma continua y la salida
demasiado pequeño
de aire es más baja que la
2. Conexiones flojas (accesorios, tubería, etc.)
presión de descarga
normal/baja.
3. Válvulas de entrada averiadas
4. Aro del pistón desgastado
Exceso de humedad en el
1. Demasiada agua en el tanque
aire de descarga
2. Humedad elevada
El compresor funciona en
1. Presostato defectuoso
forma continua y la
2. Válvula de seguridad defectuosa
válvula de seguridad se
abre cuando aumenta la
presión
Arranques y paradas
1. Demasiada condensación en el tanque
excesivas
2. Conexiones flojas (accesorios, tubería, etc.)
FP205101, FP205201
Acción a tomar
1. Asegúrese de que el compresor esté enchufado y que el
interruptor esté en la posición ON (encendido)
2. Revise el disyuntor o fusible en el panel de electricidad.
3. Libere aire del tanque hasta que el compresor se reinicie
automáticamente.
4. Deje que el compresor se enfríe durante aproximadamente
30 minutos para que el interruptor térmico de sobrecarga
vuelva a su posición normal. Asegúrese de que el compresor
esté funcionando en un área limpia y bien ventilada donde
la temperatura no exceda los 100ºF.
5. Cambie el interruptor de presión
1. Mueva el compresor a un área limpia y bien ventilada
donde la temperatura no exceda los 100ºF.
2. Cambie el ensamblaje de la bomba
1. Nivele el tanque
2. Cambie el ensamblaje de la bomba
3. Cambie el ensamblaje de la bomba
1. Apriete la válvula de drenaje
2. Cambie la válvula de retención
3. Revise todas las conexiones con una solución de agua y
jabón. Si se detecta una fuga, apriete. O quite la conexión y
aplique cinta para tuberías a las rocas y vuelva a armar.
No desarme la válvula
PELIGRO
!
de retención. Si hay
aire en el tanque, primero purgue el tanque.
1. Disminuya el uso o compre una unidad que ofrezca una
entrega de aire mayor (SCFM)
2. Revise todas las conexiones con una solución de agua y
jabón. Si se detecta una fuga, apriete. O quite la conexión y
aplique cinta para tuberías a las rocas y vuelva a armar.
3. Cambie el ensamblaje de la bomba
4. Cambie el ensamblaje del pistón
1. Drene el tanque, incline el tanque para eliminar la
humedad
2. Llévelo a un área menos húmeda, utilice un filtro de aire de
línea
Nota: La condensación de agua no es una causa para el
malfuncionamiento del compresor.
1. Cambie el interruptor de presión
2. Cambie la válvula de retención con un repuesto original
1. Drene con más frecuencia
2. Revise todas las conexiones con una solución de agua y
jabón. Si se detecta una fuga, apriete. O quite la conexión y
aplique cinta para tuberías a las rocas y vuelva a armar.
25 Sp