Power Requirements - Cisco IW3702 Getting Started Manual

Hide thumbs Also See for IW3702:
Table of Contents

Advertisement

Cisco IW3702 Access Point Getting Started Guide
Technical Specifications

Power Requirements

Table 15
Power Requirements for the Access Point
Description
DC input voltage
Maximum input current rating
1. Voltage rating is measured at the input pins of the load (IW3702) and not at the power source.
DC Input and PoE IN Specifications
The access point supports two power options:
DC input from the PWR connector.
PoE inline power from the PoE IN port.
Notes: 
The PoE OUT port is enabled only when the access point is powered over the PWR port. When
powered over the PoE IN port, PoE OUT functionality is not supported.
In relation to powering the access point:
Power can be supplied by the DC input (PWR port connection) or the PoE inline power (PoE IN port),
but not both.
We recommend not using the two power options at the same time, but no harm results if both are
present.
If both power inputs are present, the DC input (PWR port connection) takes precedence and PoE IN
becomes idle and unused.
Power supply redundancy is not supported.
Specification
12V to 48V DC (-20%, +25%)
Nominal: 12, 24, or 48 VDC
2 A @ 48 VDC
4 A @ 24 VDC
8 A @ 12 VDC
41
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents