Environmental and Operational Specifications
Table 14
Environmental and Operating Specifications for the Access Point
Description
Operating temperature
Altitude
Humidity
Extended operating temperature
(DC power)
Operating type test
Storage temperature
Vibration
Shock
Seismic
Power Specifications
Power Requirements, page 41
DC Input and PoE IN Specifications, page 41
Specification
–40 to 158°F (–40 to +70°C) with solar load and still air
15,000 ft. (4.5 m)
5 to 95% (non-condensing)
–58 to 167°F (–50 to +75°C) without solar loading, still air, and cold start limited
to –40°C
185°F (85°C) for 16 hours
–40 to 185°F (–40 to +85°C)
Per IEEE 1613, IEC 61850, EN50155, and AREMA
Per IEEE 1613, IEC 61850, EN50155, and AREMA
Per IEC 61850-3 Class 2