Technical Specifications; Power Specifications - Cisco IW3702 Getting Started Manual

Hide thumbs Also See for IW3702:
Table of Contents

Advertisement

Cisco IW3702 Access Point Getting Started Guide

Technical Specifications

Technical Specifications
This section provides the following technical specifications for the access point:
Environmental and Operational Specifications, page 40
Power Specifications, page 40
Mechanical Specifications, page 42
Regulatory Compliance and Safety Information, page 42
Declaration of Conformity for RF Exposure, page 42
Declaration of Conformity Statements, page 48
Environmental and Operational Specifications
Table 14
Environmental and Operating Specifications for the Access Point
Description
Operating temperature
Altitude
Humidity
Extended operating temperature
(DC power)
Operating type test
Storage temperature
Vibration
Shock
Seismic

Power Specifications

Power Requirements, page 41
DC Input and PoE IN Specifications, page 41
Specification
–40 to 158°F (–40 to +70°C) with solar load and still air
15,000 ft. (4.5 m)
5 to 95% (non-condensing)
–58 to 167°F (–50 to +75°C) without solar loading, still air, and cold start limited
to –40°C
185°F (85°C) for 16 hours
–40 to 185°F (–40 to +85°C)
Per IEEE 1613, IEC 61850, EN50155, and AREMA
Per IEEE 1613, IEC 61850, EN50155, and AREMA
Per IEC 61850-3 Class 2
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents