Quick Setup Parameters - Parker 890SD Quick Start Manual

Standalone drive
Hide thumbs Also See for 890SD:
Table of Contents

Advertisement

Quick Setup Parameters

The following is a list of the Quick Setup parameters you must check before starting the drive. Set
only the ones marked with "x" in the table below, under the intended mode of operation.
Control Mode
Max Speed
V/F shape
Motor Current
Motor Base Freq
Motor Voltage
Nameplate RPM
Motor Poles
Pulse Enc Volts
Encoder Lines
Encoder Invert
Autotune Enable
Mag Current
* if perfoming a Stationary Autotune.
NOTE
Some of the parameters are product code dependent, that is, they are different for each
frame size and power rating. For example, the unit will be set for either 50Hz or 60Hz
operation:
Motor Poles for 60Hz 2 poles = 3600 rpm, 4 poles = 1800 rpm, 6 poles = 1200 rpm
Motor Poles for 50Hz 2 poles = 3000 rpm, 4 poles = 1500 rpm, 6 poles = 1000 rpm
Autotune
This section is only for operating in Sensorless or Closed-loop Vector modes.
If the drive is in V/Hz mode, Autotune is unnecessary and will not Enable.
Ensure that MAX SPEED is greater than NAMEPLATE RPM for a successful autotune.
In the QUICK SETUP menu, set AUTOTUNE ENABLE to TRUE.
On the 890CD keypad select LOCAL mode. Set SETPOINT (LOCAL) to 0.0%.
Press the green RUN button. The drive will begin autotuning. The drive will stop without errors if
autotune is successful.
Go to SYSTEM::SAVE CONFIG::APPLICATION and UP arrow to save your settings.
ROTATING AUTOTUNE
Page 16
Select the intended operating mode
Motor RPM at full process speed
Usually Linear. Choose fan curve only for fans
Motor full load current from motor nameplate
Motor nameplate frequency
Motor nameplate voltage
Motor nameplate RPM
See Note
Set between 10-20V to match encoder
Pulses per Revolution of encoder
Changes polarity of encoder feedback
Drive will Autotune if started
Enter the No-Load Amps from the motor nameplate
Is the motor uncoupled
from the load and free
YES
to rotate without causing
problems?
V/Hz
NO
STATIONARY AUTOTUNE
Under QUICK SETUP, enter the exact MAG
CURRENT in Amps (from motor data)
Under Quick setup, set AUTOTUNE MODE to STATIONARY
SV
Vector
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x*
x*