Initial Setting - Pentax R-422VN Instruction Manual

R-400v series
Hide thumbs Also See for R-422VN:
Table of Contents

Advertisement

8.8 Initial setting 1

1. Selection of Atmospheric Correction: [ATM CORR]
Select whether Atmospheric Correction is to be performed
by entering the atmospheric temperature and pressure,
by entering ppm value, or by fixing the ppm value to 0
(NIL) not to perform Atmospheric Correction.
2. Selection of Prism Constant: [PRISM CONST.]
Select whether the Prism Constant to be input is set to
0mm, -30mm or to an arbitrary value to be entered from
the keyboard.
3. Selection for Reflector sheet Constant: [SHEET
CONST]
Select whether the target constant to be input is set to
0mm, or to an arbitrary value to be entered from the keyboard.
4. Selection for Refraction & Curvature Corrections
: [CRV/REF CORR]
Select whether the correction factor to be input for both
differences (Refraction, Curvature) is set to 0.14, 0.2 or
none (NIL). Selecting "3. NIL" results in no correction of
both values.
5. Selection of Tilt Compensation: [COMP AXIS]
Select whether Tilt Compensation is to be single-axis compensation, dual-axis
compensation or disabled (NIL).
R-422VN is selectable up to 3 AXIS.
R-423VN, R-425VN, R-435VN are selectable up to 2
AXIS.
The figure on the right shows that 3 AXIS is selected on
R-422VN.
6. Selection of Atmospheric corrections display: [ATM CORR DISP]
Select whether to display the atmospheric corrections in
the title bar of the measure screens or not.
• The factory default for each instrument condition is marked by
44
X
1.ATM
INPUTaXXX
2.ppm INPUT
3.NIL
X
1.-
30mmXaXXXXXX
2. 0mm
3.INPUT
X1.
0mmXaXXXXXX
2.INPUT
X
1.0.14
XaXXXXXX
2.0.2
3.NIL
X1.3
AXISXXXXXXX
2.2 AXIS
3.1 AXIS
4.NIL
X1.OFF
XaXXXXXX
2.ON
.