Olivetti d-Copia 3500MF Service Manual page 218

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U464
Setting the ID correction operation
Description
Turns ID correction (calibration) on or off. Also, this allows individual settings for calibration oper-
ation.
Purpose
To restrict calibration when poor image quality is generated. Also, this allows individual settings
for calibration depending on the user preferences.
To perform the calibration when replacing the maintenance kit.
Method
1. Press the start key.
2. Select the item to be set.
Permission
Time Interval
Mode
On/Sleep Out
AP/NE
Leaving Time
Driving Time
Timing
Target Value
Calib
Setting: [Permission]
1. Select On or Off.
On
Off
Initial setting: On
2. Press the start key. The setting is set.
Service Manual
Display
Setting to turn calibration on/off
Setting the interval time of calibration after printing
Setting the calibration execution mode
Setting execution parameters for calibration when powered up
or reverted from auto-sleep
Paper interval calibration ON/OFF setting at the time of cali-
bration/near end after toner feed
Setting the standard time for judging whether or not to carry
out calibration based on the sleep time when the machine
recovers from the sleep mode
Setting the standard time for judging whether or not to carry
out paper interval calibration based on the driving time during
printing
Setting the standard time for judging whether or not to carry
out calibration based on the continuous print driving time dur-
ing printing
Setting the sensor target values for toner thick layer calibration
and light amount calibration
Executing the calibration
Display
Turns calibration ON
Turns calibration OFF
Description
Description
Description
1-3-156
2LL/2LJ/2LH
Y113350-5

Hide quick links: