ACCURACY, RESOLUTION AND RANGE
Volt/Amps/Hertz
Vrms (ac+dc)
Fluke 435-II/437-II
Fluke 434-II
Vpk
Vrms½
Fluke 435-II/437-II
Fluke 434-II
Vfund
Fluke 435-II/437-II
Fluke 434-II
Voltage Crest Factor
(CF)
Arms (ac+dc)
i430flex-TF 1x
i430flex-TF 10x
1 mV/A 1x
1 mV/A 10x
Apk i430flex-TF
Apk 1 mV/A
A Crest Factor (CF)
Arms½
i430flex-TF 1x
i430flex-TF 10x
1 mV/A 1x
1 mV/A 10x
Afund
i430flex-TF 1x
i430flex-TF 10x
1 mV/A 1x
1 mV/A 10x
2
Hz
Fluke 435-II /437-II @ 50
Hz nominal
Fluke 435-II /437-II @ 60
Hz nominal
Fluke 437-II @ 400 Hz
nominal
info@Fluke-Direct.ca
Measurement Range
Resolution
1...600 V
0.01 V
600...1000 V
0.01 V
1...1000 V
0.1 V
1...1400 Vpk
1 V
1...1000 V phase to
0.1 V
neutral
1...1000 V phase to
0.1 V
neutral
1...1000 V phase to
0.1 V
neutral
1...1000 V phase to
0.1 V
neutral
1.0 ... > 2.8
0.01
5...6000 A (ac only)
1 A
0.5...600 A (ac only)
0,1 A
5...2000 A
1 A
0.5...200 A (ac only)
0.1 A
8400 Apk
1 Arms
5500 Apk
1 Arms
1 ... 10
0.01
5...6000 A (ac only)
1 A
0.5...600 A (ac only)
0,1 A
5...2000 A
1 A
0.5...200 A (ac only)
0.1 A
5...6000 A (ac only)
1 A
0.5...600 A (ac only)
0,1 A
5...2000 A
1 A
0.5...200 A (ac only)
0.1 A
42.5 ... 57.5 Hz
0.001 Hz
51 ... 69 Hz
0.001 Hz
340 ... 460 Hz
0.1 Hz
Fluke-Direct
Specifications
Electrical Measurements
Accuracy
± 0.1% of nominal
voltage
± 0.1% of reading
± 0.5% of nominal
voltage
5% of nominal voltage
± 0.2% of nominal
voltage
± 1% of nominal voltage
± 0.1% of nominal
voltage
± 0.5% of nominal
voltage
± 5%
± 0.5% ± 5 counts
± 0.5% ± 5 counts
± 0.5% ± 5 counts
± 0.5% ± 5 counts
± 5%
± 5%
± 5%
± 1% ± 10 counts
± 1% ± 10 counts
± 1% ± 10 counts
± 1% ± 10 counts
± 0.5% ± 5 counts
± 0.5% ± 5 counts
± 0.5% ± 5 counts
± 0.5% ± 5 counts
± 0.001Hz
± 0.001Hz
± 0.1Hz
.ca
1.800.868.7495
27
27-5