3. Replace those DIMMs.
4. Re-enable mirroring in the Setup utility.
800b0309-1301ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted. (Power Resource)
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b03091301ffff or 0x800b03091301ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0806
User Response
1. Non-redundant sufficient: Power load will be handled by remaining power supply, though the
system may throttle to avoid a power supply over-current condition.
2. Please check and reseat the lost power cord or power supply.
3. Please replace the failed power supply.
800b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b030c2581ffff or 0x800b030c2581ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Appendix A. Integrated management module II (IMM2) error messages
423