6.
Pump air into the system until both green indicators extend and water drains from both sides of the engine. The port side will
begin draining before the starboard side.
b
a
a
Closed Cooled Models
a -
Blue drain plug location
b -
Blue air pump
c -
Air manifold
d -
Green indicators
7.
Verify that water is draining from each opening. If not, use the Three Point Manual Drain System instructions.
a
8.
Allow the system to drain for a minimum of five minutes. Pump air as necessary to keep the green indicators extended.
9.
Crank the engine over slightly with starter motor to purge any water trapped in the seawater pump. Do not allow engine to
start.
10. Remove the air pump from the air manifold and return it to the mounting bracket.
90-8M0050539
MAY 2011
eng
c
d
33144
c
d
33150
Seawater Cooled Models
b
6133
Section 6 - Storage
a -
Port side drain location
b -
Starboard side drain location
Page 131