Burner And Nozzle Specifications - Indesit K6G52/U Installation And Use Manual

Hide thumbs Also See for K6G52/U:
Table of Contents

Advertisement

Available languages

Available languages

c) Minimum regulation of the hob burners:
Turn the tap to minimum;
Remove the knob and adjust the regulation screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
NB.: In the case of liquid gas, the regulation screw
must be screwed in all the way.
Check that the flame does not go out when you turn
the tap quickly from high to low.
d) Regulating the primary air of the burners: the primary
air of the burners does not need to be regulated.
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Supply
Pressures
*
A 0°C e 1013 mbar-dry gas
GZ 50
p.c.i.
35.9 MJ/m³
GZ 35
p.c.i.
25.8 MJ/m³
GPB-B p.c.i.
123.6 MJ/m³
S
S
R
A
K6G52/U
K6G56S/U

Burner and Nozzle Specifications

Thermal power
(p.c.i.*)
kW
2,70
1,70
0,90
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
Important
On completion of this operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compli-
ance with current standards regarding "regulators for chan-
nelled gas.".
Natural Gas GZ 50
Natural Gas GZ 35
Nozzle
Flow*
Nozzle
1/100
l/h
(mm)
116
285
106
180
79
95
16
20
25
22
Flow*
Nozzle
1/100
l/h
1/100
(mm)
(mm)
183
398
86
143
251
70
106
133
50
10
13
16
GPB-B
Flow*
g/h
225
142
75
29
36
44

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6g56s/u