c) Regulating the primary air of the burners: the primary
air of the burners does not need to be regulated.
Important
On completion of this operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compli-
ance with current standards regarding "regulators for chan-
nelled gas."
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Triple Ring
130
(TC)
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
S
R
TC
A
K6T72S/I

Burner and Nozzle Specifications

Thermal Power
By-Pass
kW (p.c.s.*)
1/100
Nominal
Reduced
(mm)
3,00
0,7
1,90
0,4
1,00
0,4
3.25
1.5
3
Liquid Gas
Nozzle
1/100
(mm)
***
41
86
218
30
70
138
30
50
73
63
91
236
28-30
20
35
19
Natural Gas
Flow*
Nozzle
g/h
1/100
**
(mm)
214
116
136
106
71
79
232
133
37
25
45
Flow*
l/h
286
181
95
309
20
17
25