5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Adapting the grill
Replacing the grill burner nozzle:
1. Remove the oven burner
after loosening screw V ( see
figure ).
V
2. Unscrew the grill burner
nozzle using a special nozzle
socket spanner ( see figure ) or
preferably with a 7 mm socket
spanner, and replace it with a
new nozzle that is suited to the
new type of gas ( see Burner
I
and nozzle specifications table ).
! Be careful of the spark plug wires and the
thermocouple tubes.
! The oven and grill burners do not require primary
air adjustment.
! After adjusting the appliance so it may be used
with a different type of gas, replace the old rating
label with a new one that corresponds to the new
type of gas (these labels are available from
Authorised Technical Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating
to "regulators for channelled gas".

Table of burner and nozzle specifications

Table 1
Burner
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nominal
Fast
100
3.00
(Large)(R)
Semi Fast
75
1.90
(Medium)(S)
Auxiliary
55
1.00
(Small)(A)
Oven
-
2.80
Grill
-
2.30
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
Liquid Gas
By-Pass
Nozzle
Flow*
1/100
1/100
Reduced
(mm)
(mm)
***
0.7
41
86
218
0.4
30
70
138
0.4
30
50
73
1.0
46
80
204
-
-
75
167
28-30
20
35
***
Butane
Natural
We recommend cleaning the oven before using it for the
first time, following the instructions provided in the
"Care and maintenance" section.

TECHNICAL DATA

Oven dimensions
34x39x44 cm
(HxWxD)
Volume
58 l
Useful
width 42 cm
measurements
depth 44 cm
relating to the oven
height 18 cm
compartment
Power supply voltage
see data plate
and frequency
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
Burners
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Natural Gas
Nozzle
Flow*
Nozzle
g/h
1/100
l/h
1/100
**
(mm)
(mm)
214
116
286
143
136
106
181
118
71
79
95
80
200
119
267
132
164
114
219
139
37
20
25
17
45
25
P.C.S. = 49,47 MJ/Kg
P.C.S. = 37,78 MJ/m
Flow*
l/h
S S
A
R
286
181
95
KN1G21/UA
257
KN1G21S/UA
227
13
6,5
18
3
GB