The #93 Menu Mode is an interactive mode through which much of the system's programming is done. In this mode,
there are "question and answer" prompts are accessed once Data Field Program Mode has been entered. These prompts
require a 2-line alpha keypad (6160).
After programming all system-related programming fields in the usual way, press #93 while still in programming mode to
display the first choice of the menu-driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed
menu selection. Pressing 0 will display the next choice in sequence.
Below is a list of the main menus:
MAIN MENU
ZONE PROG?
1 = YES 0 = NO
0
EXPERT MODE?
1 = YES 0 = NO
0
REPORT CODE PROG?
1 = YES 0 = NO
0
ALPHA PROG?
1 = YES 0 = NO
0
DEVICE PROG?
1 = YES 0 = NO
0
OUTPUT PGM?
1 = YES 0 = NO
0
RLY VOICE DESCR?
1 = YES 0 = NO
0
CUSTOM INDEX ?
1 = YES 0 = NO
0
ACCESS POINT PGM
1 = YES 0 = NO
0
ACCESS GRP PGM
1 = YES 0 = NO
0
EVENT/ACTION PGM
1 = YES 0 = NO
0
r
o
g
r
a
m
m
i
n
g
P
r
o
g
r
a
m
m
i
n
g
OPTIONS
For programming the following:
Zone Number
Zone Response Type
Partition Number for Zone
Dialer report code for zone
Same as Zone Programming except:
Done with a minimum number of keystrokes.
Can program wireless keys using pre-defined templates.
For programming the following:
Alarm report codes for zones
Restore and supervisory codes
All other system report codes
For entering alpha descriptors for the
following:
Zone Descriptors
Installer's Message
Custom Words
For defining the following device characteristics for addressable devices, including keypads, RF receivers
(5881), output relay modules (4204), and AlarmNet ECP Communicators:
Device Address
Device Type
Keypad Options (including Partition assignment)
RF House ID
LRR Options (including Programming radio)
For defining output device functions.
Not Used.
Not Used.
For defining the parameters for each of the VistaKey zones, including which group(s) have access
through an access point (door). See the VistaKey-SK Installation and Setup Guide for detailed
programming instructions.
For defining the capabilities (privileges) for each group of users. See the VistaKey-SK Installation and
Setup Guide for detailed programming instructions.
For defining events and time windows for an access group. See the VistaKey-SK Installation and Setup
Guide for detailed programming instructions.
Input Device Type for zone (whether RF, polling
loop, etc.)
Enrolling serial numbers of 5800 Series
transmitters & serial polling loop devices into the
system.
Zone Attributes (e.g., Arm w/Fault, Silent, etc.).
Partition Descriptors
Relay Descriptors