Sia Cp-01 Quick Reference Chart; Required Sia Programming Locations; Required Sia Features - Honeywell VISTA-128BPT Programming Manual

Burglary partitioned security system
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
S
I
A
C
P
-
0
1
Q
u
i
S
I
A
C
P
-
0
1
Q
u
The minimum required system for SIA CP-01 is a VISTA-128BPTSIA Control, one of the following model keypad; 6160,
TUXS, TUXW, 6280S, or 6280W and a UL Listed Bell.
R
e
q
u
i
r
e
d
S
I
A
P
r
o
g
R
e
q
u
i
r
e
d
S
I
A
P
r
o
Item
Feature
∗09
Entry Delay # 1
∗10
Exit Delay #1
∗11
Entry Delay # 2
∗12
Exit Delay #2
∗28
Power Up in Previous
State
∗57
Dynamic Signaling
Priority
∗84
Swinger Suppression
∗88
Abort Window Time (for
non-fire zones)
Exit Time Reset
1∗21
1∗22 –
Cross Zoning
1∗25
1∗42
Call Waiting Defeat
Abort Verify
1∗61
R
e
q
u
i
r
e
d
S
I
A
F
e
a
R
e
q
u
i
r
e
d
S
I
A
F
e
a
Item
Zone Programming
Auto Stay Zone, Zone
type 04 has this
feature enabled by
default
Zone Programming
(Abort Window
Enable)
Zone Programming
(Swinger Suppression
Enable)
Zone Programming
Tamper Option
S
E
S
E
c
k
R
e
f
e
r
e
n
c
e
i
c
k
R
e
f
e
r
e
n
c
e
r
a
m
m
i
n
g
L
o
c
a
t
i
g
r
a
m
m
i
n
g
L
o
c
a
t
i
02 – 15 multiplied by 15 seconds
00 = 240 sec (4 minutes)
03 – 15 multiplied by 15 seconds
02 – 15 multiplied by 15 seconds
00 = 240 sec (4 minutes)
03 – 15 multiplied by 15 seconds
0 = no
1 = yes
0 = primary dialer
1 = Communicator as first
reporting destination
01-06 = 1-6 alarms
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
0 = no
1 = Resets Exit Delay to
programmed value
after zone is closed
and then faulted prior
to end of exit delay.
Zone 001 – 250
000, 000 = Disabled
0 = no
1 = yes
0 = Disable
1 = Enable
t
u
r
e
s
t
u
r
e
s
Feature
Auto Stay Arm or Occupied
Premises
Abort Window (for non-fire
zones)
Swinger Suppression Enable
Fire Alarm Verification
C
T
I
O
N
:
1
C
T
I
O
N
:
1
C
h
a
r
t
C
h
a
r
t
o
n
s
o
n
s
Range
30 Seconds`
60 Seconds
30 Seconds
60 Seconds
Yes
0 (primary dialer)
2 alarms
30 Seconds
1 (Enabled)
Disabled
Disabled (0)
Enabled
Range
0 = Disable
1 = Enable
0 = no abort window
1 = yes, use abort window
according to ∗88
selection
0 = no suppression
1 = yes, suppress alarms
according to ∗84
selection
For Zone Response Type
16 (Fire) tamper selection
must be set to "0"
1
S
I
A
C
P
-
0
1
S
I
A
C
P
-
0
1
Shipping
SIA Requirement*
Default
At least 30 Seconds **
60 Seconds
At least 30 Seconds **
60 Seconds
Yes
0 (primary dialer)
1 alarm
At least 15 Seconds **
1 (Enabled)
Enabled and two (or more)
zones programmed
Enabled if user has call
waiting
Enabled
Shipping
Default
1 (Enabled)
1 = yes
Yes
(enabled)
Disabled
T
A
B
L
E
T
A
B
L
E
SIA
Requirement*
Enabled
Yes (all non-fire
zones)
Yes (enabled (all
zones))
Enabled unless
sensors can self
verify

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia