Kyocera FS-9120DN Service Manual page 55

Hide thumbs Also See for FS-9120DN:
Table of Contents

Advertisement

FS-9120DN/9520DN
Maintenance
item No.
U196
Turning the fixing heater on
Description
Turns the fixing heater M or S on.
Purpose
To check fixing heaters turning on.
Method
1. Enter the maintenance mode and press the
>Turn Fixing
[U196] Heater ON
2. Press the
3. Press the
Display
Main Heater ON
Sub Heater ON
4. Press the ENTER key. "Execute" will be displayed and the heater will be turned on for three seconds.
Note
Do not open or close the cover when the heater is on. Either do not turn on the heater continuously.
>>Main Heater ON
[196.1] Execute
5. To turn off the heater, press the ENTER key or the CANCEL key.
U198
Setting the fixing phase control
Description
Sets the use of fixing phase control to reduce electrical noise generated.
Purpose
Normally no change is necessary. If electrical noise generated by the machine causes flickering of the lights
around the machine, select fixing phase control to reduces the noise.
Method
1. Enter the maintenance mode and press the
2. Press the ENTER key. "?" will be displayed.
3. Press the
>Phase Control
[U198]? Off
4. Press the ENTER key. The setting is set.
To keep the preset value, press the CANCEL key.
1-4-22
>
key to display the submenu screen.
or
key to select the heater to turn on.
or
key to select on or off.
Description
or
key to display "U196".
Description
Fixing heater M (FH-M)
Fixing heater S (FH-S)
or
key to display "U198".