(2) Detaching and refitting the MP separation, MP paper feed and MP forwarding pulleys
Follow the procedure below to replace the MP separation, MP paper feed and MP forwarding pulleys.
Procedure
• Removing the MP tray unit
1. Remove the four screws holding the lower
right cover and then the cover.
2. Remove the two screws holding the MP tray
unit and disconnect the two connectors, and
then remove the unit.
• Removing the MP separation pulley
3. Reverse the MP tray unit and remove the
spring and stop ring from the MP separation
pulley and move the bushing inside.
1-6-4
Lower right cover
Figure 1-6-7
Figure 1-6-8
Bushing
MP separation shaft
Spring
Figure 1-6-9
Connectors
MP tray unit
Stop ring