4. Raise the MP separation shaft as shown in
the diagram, remove the holder plate and the
bushing, and then remove the MP separation
pulley.
* Take care not to remove the spring pin of the
gear at the rear of the MP separation shaft. If
it is removed, refit it to its original position.
• Removing the MP paper feed pulley
5. Detach the connector of the MP paper switch
and remove the wire from the three clamps.
6. Remove the screw holding the MP tray unit
cover and then the cover.
7. Remove the stop ring and bushing on the
front of the MP paper feed shaft.
Holder plate
Bushing
MP separation pulley
Figure 1-6-10
Clamps
Figure 1-6-11
MP paper feed shaft
Figure 1-6-12
FS-9120DN/9520DN
MP separation shaft
MP unit cover
Connector
Stop ring
Bushing