Install the 8-bay SFF hot-plug drive cage assembly in box 2.
14.
If two 8-bay SFF hot-plug drive cages are installed, install the storage controller
15.
storage controller and FBWC module
Connect the drive cage cables. See "8-bay SFF hot-plug drive cabling (on page 86)." Then, install
16.
the drives.
Install the system air baffle (on page 22).
17.
If removed, install the PCI air baffle
18.
Install the front bezel (on page 19).
19.
Install the access panel (on page 18).
20.
Return the server to an upright position.
21.
Connect each power cord to the server.
22.
Connect each power cord to the power source.
23.
Power up the server.
24.

Drive options

For a list of drive configurations supported in this server, see "Drive numbering (on page 13)."
The embedded storage controller supports SATA drive installation. For SAS drive installation, install a
Host Bus Adapter or a Smart Array Controller board option.
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).

Drive installation guidelines

When adding drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
Populate drive bays, based on the drive numbering sequence. Start from the drive bay with the
lowest device number
All drives grouped into the same drive array must meet the following criteria:
They must be either all SAS or all SATA.
o
options" on page 45).
("Install the PCI air
("Drive
numbering" on page 13).
baffle" on page 20).
Hardware options installation 36