Setting Home Position

Similar to a standard actuator, the IntelliValve
point positions are 0 and 24 with the "Home" position at 0. This is the diverter end point at
which the diverter normally resides. Positions 0 and 24 LEDs represent the center of the
diverter and are equivalent to OFF (no water flow through outlet) on a standard actuator.
For examples of IntelliValve diverter positions showing the relationship between the LEDs
and the diverter position see pages 13 to 16.
SET Mode (Using Red and Yellow Arrow Buttons)
The following steps describe how to change the factory default 0 and 24 position, with
"0" being home position or starting from a custom home position.
To change the diverter travel end points:
1.
Press MODE button until SET Blue LED is ON.
2.
Press the Red arrow or Yellow arrow button to set the desired first end
point position of the diverter nearest to 0. This is the diverter return end
point after you set the second end point (see Step 3). Press SAVE. The
return end point Red LED will flash.
3.
Press the Red arrow or Yellow arrow button to set the desired second end
point position of the diverter nearest to 24. Press SAVE. The second end
point LED diverter position (Red LED) will flash.
4.
All the LEDs in the path of travel will flash five (5) times, then the LED for
the last set end point will remain on.
5.
The end points are now established and the MODE changes to Service
(Yellow LED on).
6.
Press and release the MODE button and the AUTO LED (Green) turns on
and the diverter stays in or moves to the home position and the diverter
location LED will remain lit (Red). The actuator can now be checked for
proper operation. Note: Only two end point positions can be set. Setting
the two end point diverter positions allows the water flow through the valve
to achieve the desired effect. See example on page 13.
(counterclockwise rotation)
7.
Changing Home Position: If the current diverter home position
which the diverter moved to is not the desired home position for the
application, simply press and release both the Red and Yellow arrow
buttons simultaneously to move the diverter home position to the
opposite end point. This is now the diverter home position. For more
information see page 11.
Red arrow button
Diverter
Position 0
(Red LED)
Set
(Blue LED)
Home position 0 LED (Default Setting)
Valve Actuator factory default diverter end
Yellow arrow button
(clockwise rotation)
INTELLIVALVE
Valve Actuator Installation and User's Guide
Mode button
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

522301

Table of Contents