Access Levels - IVT Rego 5101 Installation Manual

Table of Contents

Advertisement

B Use
for more information under Info.
External sensors
E11.T1
E11.T1 spv
E10.T2
Tab. 23 External sensors 1
Shows the actual value for a given sensor and the set
point for E11.T1.
External sensors
E41.T3
Stop
E41.Q11
Tab. 24 External sensor 2
Shows the actual value and stop temperature for the hot
water sensor as well as the mixing valve position. Is only
shown in heat pumps that produce hot water.
Internal sensors
T6 87.0
T8 36.2
T9 29.2
Tab. 25 Internal sensors
Shows the actual value for the given sensors.
Status digital I/O
vvvvv1 2 3 4 5 6 7 8
In: vv0 0 0 1 1 1 1 1
Out: 1 0 0 0 1 0 1
Tab. 26 Status digital I/O
0 = Off, 1 = On (
Chapter 2, page 4 for information on
I/O-connections).
Status analogue out
Ao1: 0.0
Ao2: 0.0
Ao3: 0.0
Tab. 27 Status analogue out
Shows present utilisation in % (
information on I/O-connections).
Program version
x.x – x – xx
Tab. 28 Program version
B Use
several times to return to the Initial menu.
Information is also available at different places in the
menus, e.g. under Temperatures at the top menu level.
6 720 645 172 (2010/07) en
35:2 °C
36.2 °C
3.9 v °C
56.4 °C
57.0 °C
Off
( °C)
T10 5.0
T11 2.0
(%)
Ao4: 64:3
Ao5: 52.8
Chapter 2, page 4 for

3.11 Access levels

Not logged in
See a small number of settings.
Customer
See and change customer settings.
Logging out after 10 min.
Installer
According to the Customer and see
and change more settings. Logging
out after 30 min.
Tab. 29 Access levels
Log in must be done per heat pump.
Log in as a customer:
B Press
for 5 seconds in the Initial menu.
ok
Log in as installer:
B Enter password mmdd under Access level.
mm = current month
dd = current day
E.g.: 0315 = 15th March.
Logging out:
B Use function Quick log-out on installer level or wait.
Control panel
9