Settings
4.5
Settings\Hot water
Setting
Hot water
Hot water type
Temperatures
Tab. 36 Hot water
18
When the heat pump is to produce hot water:
B Enter how the heat pump is to control hot water production.
B Select Local sensor when there is a locally connected hot water cylinder with local sensor to
measure the hot water temperature.
B Select Previous HP when the heat pump receives values for the hot water temperature from
the previous heat pump.
B Select Communicated when the heat pump has all information about the hot water
temperature and start/stop limits via communicating (Modbus) control (
page 10).
Actual v.:
Start:
Stop:
Max temperature:
B Set start and stop values for hot water production.
The factory settings refer to heat pumps with Local sensor. In Previous HP 2 K lower
temperatures are recommended. In Communicated the values have no meaning.
Max temperature displays the calculated possible highest hot water temperature.
Factory
No hot water
Display
53 °C
57 °C
Display
Range
No hot water
Local sensor
Communicated
Previous HP
Not E21
Chapter 4.1,
6 720 645 172 (2010/07) en
HP
E2x
E2x