Control panel

3.10 Operating information

Rego 5101
2010-03-01
Outd. -2:0 °C
Tab. 19 Initial menu
Under Info there is operating information that is reached
by pressing
in the initial menu.
Operating mode
Demand
Status compr.
Tab. 20 Info 1
Operating mode: Winter operation or Summer
operation.
Demand: Shows one of the following:
No demand
No demand for heating, hot water or
external start of the compressor.
Heating
Heating demand
demand
Hot water
Hot water demand
demand
Therm.
Thermal disinfection
disinfection
External
An external unit has demanded
operation
operation of the heat pump,
compressor and/or additional heat.
Manual
Function test underway.
operation
Tab. 21 Need
8
E21
14:23
Menu>
Info
Time
Status compressor: Shows one of the following:
Blocked
The compressor is blocked by a
tripped safety function. Information
is stored in Alarm history available at
installer level.
External
The compressor is blocked via
blocking
external control.
Off
The compressor is not running.
E11.G1 is running in case of winter
operation or anti-seizure operation.
Q21/E4x.Q1x is active in case of
emergency operation, summer or
anti-seizure operation. Additional
heat is not in operation.
Press. equal.
The compressor restart timer is
counting down. The time remaining
in seconds is shown.
Start-up
When a demand occurs, G2 and G3
start first and run for 30 seconds to
verify function.
Checking
After start-up the temperatures T6,
T8, T9, T10, T11 are checked for 3
minutes to ensure that they can
manage the protection
temperatures.
Compressor
The compressor starts. T6 must rise
to a minimum of 10K above T8
within 3 minutes, otherwise the
compressor stops.
Operation
The compressor runs as long as the
demand remains or external start is
active. No safety functions have
tripped, and there is no external
stop.
Stopping
The compressor has stopped in this
situation. G2 and G3 run for 2
minutes. The time remaining in
seconds is shown.
Oper.+
Both the compressor and the
Add.heat
additional heat are in operation.
Tab. 22 Status compressor