Settings\Collector Circuit; Settings\External Control; Settings\General Alarm; Settings\Inversions - IVT Rego 5101 Installation Manual

Table of Contents

Advertisement

4.8

Settings\Collector circuit

Setting
Collector circuit
Collector circuit
Tab. 39 Collector circuit
4.9

Settings\External control

Setting
External control
External input B11
Select function:
Tab. 40 External control

4.10 Settings\General alarm

Setting
General alarm
General alarm
Tab. 41 General alarm

4.11 Settings\Inversions

Setting
Inversions
Digital inputs
Di1
Di2
Di3
Tab. 42 Inversions
6 720 645 172 (2010/07) en
T10: Start
T10: Stop
T11: Start
T11: Stop
Set the suitable values for collector circuit in (T10) and out (T11).
B
B For rock/earth – 5, – 8, – 5, – 8 °C (factory settings) are recommended.
B 1, 0, 0, – 3 °C is recommended for exhaust air.
B 4, 3, 3, 0 °C is recommended for groundwater.
B Select the function applicable for how the external input B11 (Di2) must affect the heat pump
when the input closes.
B Select whether the general alarm output Do7 is to be activated for both A and B alarms or only
for A alarms.
B Select Inverted if the unit connected to the input requires it.
Factory
– 5 °C
– 8 °C
– 5 °C
– 8 °C
Factory
Block all
Factory
A/B alarm
Factory
Normal
Normal
Normal
Range
– 8 °C – +30 °C
– 8 °C – +30 °C
– 8 °C – +30 °C
– 8 °C – +30 °C
Range
No effect
Block all
Block add. heat
Block compressor
Block hot water
Start comp+add.heat
Start compressor
Range
A/B alarm, A alarm
Range
Normal, Inverted
Normal, Inverted
Normal, Inverted
Settings
HP
E2x
HP
E2x
HP
E2x
HP
E2x
25