Settings\Additional Heat - IVT Rego 5101 Installation Manual

Table of Contents

Advertisement

Settings
4.4

Settings\Additional heat

The tables display the settings for different types of
additional heat:
• Internal add. heat E2 (3 step)
• District heating E51
Setting
Additional heat
Additional heat type
Settings
ECO-drive
Tab. 33 Internal electric additional heat
14
B Set applicable Additional heat type and desired additional heat operation. In Internal add.
heat is shown:
Start E2.E1
Hysteresis
Delay
Actual v.:
Start E2.E2
Delay
Actual v.:
Start E2.E3
Delay
Actual v.:
Stop E2.E1
Delay
Actual v.:
Stop E2.E2
Delay
Actual v.:
Stop E2.E3
Delay
Actual v.:
Settings
Max no. of steps in:
Heating:
Hot water:
B Set conditions for when respective stages must connect/disconnect.
B Set how many steps may be used as a maximum for heating mode and hot water mode.
ECO-drive
Start
Stop after
B Indicate Yes if activation of the additional heat is to be delayed during a set time period.
The delay increases by 25% for the first stage.
• Modulated add. heat E71
• Mixed add. heat E71
B Read more about additional heat (
4.4.7).
Factory
No additional heat
Comp. + add. heat
3 K
180 °min
Display, can be changed
60°min
Display, can be changed
60°min
Display, can be changed
10°min
Display, can be changed
5°min
Display, can be changed
5°min
Display, can be changed
2
2
No
22:00
6 hr
Chapter 4.4.1 -
Range
No additional heat
Internal add. heat
District heating
Modulated add. heat
Mixed add. heat
Only additional heat
Comp. + add. heat
Only compressor
0, 1, 2, 3
0, 1, 2, 3
No, Yes
00:00 - 23:59
6 720 645 172 (2010/07) en
HP
E21
E21
E21