4.15 Read out

Read out/Setting
Read out
I/O-status
Temperatures
Operating times
Logging
Alarm history
Program version
Tab. 46 Reading

4.16 Quick log-out

Setting
Quick log-out
Quick log-out
Current level:
Tab. 47 Quick log-out
6 720 645 172 (2010/07) en
Digital inputs
Read status of the inputs. Displayed as 0 (Off) or 1 (On).
B
Digital outputs
Read status of the outputs. Displayed as 0 (Off) or 1 (On).
B
Analogue inputs
Read temperatures for the inputs.
B
Analogue outputs
Read opening degree/speed in % for the outputs.
B
Internal sensors
Read off temperatures for sensor T6, T8, T9, T10, T11.
B
External sensors
Read temperatures for sensor E11.T1, E10.T2, T3. The set point for E11.T1 and stop
B
temperature for T3, valve and valve operation mode are also shown.
Total
Read the total number of starts and hours for Compressor, Hot water, Winter operation,
B
Additional heat.
Additional heat is displayed in E21.
Short time
Read the number of starts and hours for Compressor, Hot water, Winter operation,
B
Additional heatfor the time after reset.
Additional heat is displayed in E21.
Alarm settings
Indicate Yesif short run time will be monitored for Heatingand/or Hot water.
B
Information alarm Short oper. time in heating modeand/or Short oper. time in hot water
modecan now perform (
Heating, Additional heat, Hot water, etc
Set a number of hours back in time and see the status/temperatures etc at that point in time.
B
The values are stored each whole hour and 168 hours (=1 week) are stored.
B Use
and
to scroll between the different windows.
Additional heat is displayed in E21.
Alarm history
Read all alarms and information messages, the latest is shown first.
B
B Use
and
to browse to the required alarm.
The alarm history contains the most recent 20 messages.
Program version
Read the current program version for the control unit.
B
B Indicate Yes to log out and return to the initial menu.
Chapter 5.6.44, 5.6.45, page 35).
Factory
No
Display
Settings
HP
E2x
E2x
E2x
E2x
E2x
E2x
E2x
E2x
E2x
E2x
E2x
E2x
Range
HP
No, Yes
E2x
27