Mounting and installing the modules

When mounting and installing the SIMODRIVE modules on the rear cabinet
panel, proceed in the following sequence:
1. Screw–in the retaining screws up to a clearance of approx. 4 mm from the
2. Locate the modules in the screws and then tighten the screws with 6 Nm.
3. Locate the DC link connecting bar in the adjacent module under the screws
The DC link covers must only be installed with the power turned off. Check the
spring elements for exact positioning prior to installation. Covers with warped
spring elements must be replaced.
Drive bus
For drives with a digital setpoint interface, a drive bus cable is required for the
control and communications interface SINUMERIK 840D powerline (refer to
Fig. 2-1).
Table 2-1
for module width
S
S
S
S
In order to jumper monitoring/pulsed
resistor modules, select the drive bus
cable to be 50 mm longer!
S
S
Equipment bus
The electronics power supply between the individual modules is established
using the equipment bus cable (refer to Fig. 2-1). The equipment bus cable is
included in the scope of supply of the power module.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
2.1 Arrangement of the modules and their mounting
surface of the mounting panel.
provided and tighten these screws with 1.8 Nm –0/+30%.
Order number assignment
Designation
50 mm
100 mm
150 mm
300 mm
350 mm round long cable
200 mm long ribbon cable
2 System Configuration
Order number (MLFB)
6SN11 61–1CA00–0AAj
6SN11 61–1CA00–0BAj
6SN11 61–1CA00–0CAj
6SN11 61–1CA00–0DA0
j ––> 0: Ribbon cable
j ––> 1: Round cable (control units required
from six axes onwards)
6SN11 61–1CA00–0EA1
6SN11 61–1CA00–0FA0
2