6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Outdoor Unit
No. Parts name
1
Compressor
2
Outdoor fan motor
3
Reactor
4
Reactor
5
4-way valve coil
6
PMV coil
7
P.C. board (Main PCB)
8
P.C. board (Control PCB)
9
P.C. board(Display PCB)
10
Fuse (Mounted on P.C. board MCC-1645) ―
11
Fuse
12
Fuse (Mounted on P.C. board MCC-1645、
MCC-1665)
13
Outdoor temp. sensor (TO sensor)
14
Evaporator temp. sensor (Te sensor)
15
Discharge temp. sensor (Td sensor)
16
Suction temp. sensor (Ts sensor)
17
Temp. sensor at A room gas side
(TGA-sensor)
18
Temp. sensor at B room gas side
(TGB-sensor)
19
Temp. sensor at C room gas side
(TGC-sensor) *only 3M series)
20
Compressor thermo.
21
Terminal block (6P)
22
Terminal block (3P)
*only 2M series)
23
P.C. board(DRC PCB)
24
Transformer for DRC
25
High-pressure SW
Model name
DA136A1T-40N
ICF-140-43-4R
CH-57
CH-76
SQ-D27012-000752
CAM-MD12TCTH-5
MCC-1645
MCC-1665
MCC-1646
CS-12AL
MCC-1653
VT-02
ACB-4UB83W
- 35 -
FILE NO. SVM-15102
Rating
Output 43W
10mH、16A
9.9mH、1A
DC12V
DC12V
AC220-240V
AC220-240V
AC220-240V
AC250V、25A
AC250V、6.3A
AC250V、3.15A
10kΩ (25℃)
10kΩ (25℃)
50kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
ON:90℃、OFF:125℃
AC250V、20A
AC250V、20A
AC220-240V
Output AC14V
OFF:4.15MPa