2-2-1.
SUMMARIES OF PRODUCT CHARACTERISTICS
RAS-2M18S3AV-A
T
AS/NZS 4755.3.1.
These models supports DRM1 DRM2 DRM3.
AS/NZS 4755
DRM1
Demand response mode
DRM1
DRM2
DRM3
*1: E30m = total electrical energy (kWh) used by the air conditioner for all purposes (including compressors,
controls and fans) over a 30 min period.
*2: R = rated input electrical power of the air conditioner (kW) at rated capacity in the mode in which it is
operating during the demand response event (i.e.cooling or heating).
DRED installation position
Outline of DRED wiring
Demand response interface
CN101
Trans-
MCC-1653
former
CN102
COM DRM1 DRM2 DRM3
COM DRM1 DRM2 DRM3
DRED
Locally procured
DRM2
DRM3
Description
Compressor off
E30m ≤ R × 0.50 × 0.5
E30m ≤ R × 0.75 × 0.5
CN100
Outdoor control
P.C. board
CN105
L
N
Power supply
Indoor (A and B) unit