No. Part name
③ Inverter
10) Disconnect the leads connected to the other
assembly
parts from the P.C. assembly.
(continued)
These connectors have the lock. The lock must
be released before they are disconnected.
Main P.C. board
CN300 : Outdoor fan motor (3P : white)
CN500 : Thermostat for compressor (2P : blue)
CN501 : High pressure switch (3P : green)
CN704 : 4 way valve coil (2P : white)
Control P.C. board
CN01 : AC-IN (2P : Red)
CN02 : Sirial connunication (3P : Black)
CN600 : TD sensor (3P : white)
CN601 : TE sensor (2P : white)
CN602 : TO sensor (2P : white)
CN603 : TS sensor (3P : white)
CN604 : TGa sensor (2P : yellow)
CN605 : TGb sensor (2P : red)
CN606 : TGc sensor (2P : green)
CN609 : Demand response connector (3P : pink)
CN700 : PMV A (6P : yellow)
CN701 : PMV B (6P : red)
CN702 : PMV C (6P : green)
CN805 : Display P.C. board (10P : white)
Connected connector of main and control
CN806 and CN802 (5P : blue)
11) Remove the heatsink.
  (ST2TØ3×12L 5pcs.)
12) Remove the PCB base.
When mounting the new control board assembly,
ensure that the P.C. board is inserted properly into
the P.C. board support groove.