9.26 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Status Message
Specifies whether the Status Message is sent to the network.
Value Range
No Transmission: Status Message is not sent.
When error detection (Mandatory): Send the Status Message when an error (Mandatory) is detected.
When error detection (Option / Mandatory): Send the Status Message when an error (Option or Mandatory) is
detected.
Maintenance Console Location
9.26 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Status Receive
Selects what happens to a call when the Status Message from the network does not match the actual status
of the call.
Value Range
Ignore: Ignore the Status Message from the network.
Disconnect: Disconnect the call.
Maintenance Console Location
9.26 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
CRC4 Mode
Enables the use of CRC4 for error checking. CRC (Cyclic Redundancy Check) is an error checking control
technique that uses a specific binary prime divisor that results in a unique remainder. It is usually a 16- to
32-bit character. (Assignable only when using the PRI30 card.)
Value Range
Disable, Enable
Maintenance Console Location
9.26 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
CO Setting
CO Setting parameters are not applicable to ports assigned as Extension in
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Port Type
Selects the port type.
Note
Each ISDN connection in a QSIG network must have a master port on one PBX and a slave port on
another PBX.