Table 3-4 (Page 3 of 5). Firmware Checkpoints.
Checkpoint
Description
F75
BootP request
F9E
Real time clock (RTC) initialization
FDC
Dynamic console selection.
FDD
Processor exception
FDE
Alternating pattern of FDE and FAD
indicates a processor exception has
been detected.
3-16
7043 43P Series Service Guide
Action/
Possible Failing FRU
Refer to "Fxx Code Boot Problems"
on page 3-18 for general
considerations.
1. Turn off then on, and retry the
boot operation.
2. Verify the network connection
(network could be down).
3. Verify that IP paramters are
correct.
4. Have network administrator
verify the server configuration
for this client.
Refer to error code 28030xxx in
"Firmware Error Codes" on
page 3-4.
Refer to "Fxx Code Console
Problems" on page 3-20.
1. Verify that only supported
system memory DIMMs are
installed.
2. If more than one DIMM is
installed, swap each DIMM to a
different socket.
3. System Board (See notes on
page 3-1.)
4. For Model 240, processor
cards.
1. System board (See notes on
page 3-1.)
2. For Model 240, processor
cards.