Table 3-2 (Page 4 of 9). Firmware Error Codes.
Error Code
Description
002
Test Unit Ready Failed - sense data
available
003
Send Diagnostic Failed
004
Send Diagnostic Failed - DevOfl cmd
21E00xxx
SCSI Tape
21ED0xxx
SCSI Changer
21EE0xxx
Other SCSI device type
21F00xxx
SCSI CDROM
21F20xxx
SCSI Read/Write Optical
25010xxx
Flash
xxx=000
No diskette in drive
001
Diskette seek error
002
Diskette in drive does not contain an
*.IMG file.
003
Cannot open OPENPROM package
004
Cannot find OPENPROM node
006
System id does not match image
system id
007
Image has bad CRC
008
Flash is write protected, update
cancelled
009
Flash module is unsupported or not
recognized
Chapter 3. Error Code to FRU Index for Model 140 and Model 240
Action/
Possible Failing FRU
1. Media (Removable media devices)
2. SCSI device
1. SCSI device
1. SCSI device
Refer to 21A00xxx (SCSI disk drive) for
xxx definitions
Refer to 21A00xxx (SCSI disk drive) for
xxx definitions
Refer to 21A00xxx (SCSI disk drive) for
xxx definitions
Refer to 21A00xxx (SCSI disk drive) for
xxx definitions
Refer to 21A00xxx (SCSI disk drive) for
xxx definitions
Insert diskette containing firmware
image.
1. Retry function
2. Replace diskette drive
3. Replace diskette cable
4. Replace system board (See notes
on page 3-1.)
Insert diskette with firmware update file.
Replace system board. (See notes on
page 3-1.)
Replace system board. (See notes on
page 3-1.)
Make sure correct firmware update
diskette is being used with this system.
Replace firmware updated diskette
1. Turn off, turn on system unit and
retry.
2. Replace system board. (See notes
on page 3-1.)
Make sure correct firmware update
diskette is being used with this system.
3-7