Firmware Error Codes

If you replace FRUs and the problem is still not corrected, go to MAP 0030 in the
Diagnostics Information for Multiple Bus Systems unless otherwise indicated in the
tables.
Table 3-2 (Page 1 of 9). Firmware Error Codes.
Error Code
Description
20100xxx
Power Supply
20A80xxx
Remote initial program load (RIPL)
error
xxx=000
Insufficient information to boot.
001
Client IP address is already in use by
other network device
002
Cannot get gateway IP address
003
Cannot get server hardware address
004
Bootp failed
005
File transmission (TFTP) failed
20D00xxx
Unknown/Unrecognized device
xxx=00F
Self-test failed on device, no
SRN/location code information available
010
Self-test failed on device, can't locate
package.
20E00xxx
Security
xxx=000
Power on Password entry error.
001
Privileged-access password entry error.
002
Privileged-access password jumper not
enabled.
3-4
7043 43P Series Service Guide
Action/
Possible Failing FRU
Verify the IP address.
Change IP address.
Refer to "Firmware Checkpoints" on
page 3-14 table using code F74.
Refer to "Firmware Checkpoints" on
page 3-14 table using code F74.
Refer to "Firmware Checkpoints" on
page 3-14 table using code F75.
Check network connection, try again.
Check the System Management
Services error log entry (if present) for
the location code of the failing device.
The error log is described in "Step
1020-4" on page 2-11
If the error code specifies a network
adapter, see 3-1.
Contact your service support
representative for assistance.
Retry installing the password.
Retry installing the password.
The privileged-access password jumper
is not in the correct position for
password initial entry.
Consult the system's User's Guide for
jumper location and position.

Hide quick links: