Avaya D100 Installation And Administration Manual page 62

Ip office sip wireless terminal
Hide thumbs Also See for D100:
Table of Contents

Advertisement

Administration and maintenance
Diagnostics
The following table contains a summary of the diagnostics available for the D100 base station.
If any of the following diagnostic checks fail to complete, reboot the base station. If problems
persist, the hardware might need replacing.
The administrator performs the diagnostic checks on the handset through the Diagnostics
menu, which only the administrator can enter.
Item
LED Check
KEY Check
RAM Check
PHY Check
Flash Check
RF Check
Procedure
1. From the Administrator Setting menu, use the Next and Prev soft keys to navigate
2. Navigate the diagnostics submenu and select the desired item using the Select soft
62
D100 SIP Wireless Terminal Installation and Administration Guide
To check the operation of the LED.
The Power LED flashes for three seconds, followed by the Status LED for
the same duration. The message Checking LED also flashes on the
display during the check.
If the check fails, the LED does not display the correct status.
To check the operation of the Registration Key on the base station.
The display reads Hold Reg. Key. When you hold the Registration key,
the base station detects the registration.
If the base station fails detection, the Registration key does not perform
registration.
To check the status of the RAM.
The message Checking RAM flashes on the display.
If the check fails, the base station might behave unexpectedly.
*Can be run in maintenance mode using the Base Station Web
Management Interface*
To check the status of the PHY register.
If the PHY check is successful, press the Details soft key to view more
information on Link, Duplex, and Speed.
If the check fails, the base station cannot connect to IP Office.
*Can be run in maintenance mode using the Base Station Web
Management Interface*
To check the status of the flash memory.
The message Checking Flash flashes on the display.
If the check fails, the base station might behave unexpectedly.
*Can be run in maintenance mode using the Base Station Web
Management Interface*
To check the status of the RF register.
If the check fails, the base station cannot transmit data to the handset
correctly.
*Can only be invoked using the Base Station Web Management Interface*
to Diagnostics and press the Select soft key.
key.
Comments? infodev@avaya.com
Purpose/Behaviour
December 2012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents