Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
9.2
Assembly
9.2.1
Attach the color LCD
Take a LCD Assembly and place it on the Main Board and fasten the connector to the LCD Connector which is
located on the Main Board.
In case of replacement by a new LCD do not forget to remove the Peel-off from the LCD.
9.2.2
Replace Keypad Holder
Align the keypad holder below the LCD metal frame. Press firmly at both sides to make sure that the two side clips
click on the Main Bord.
Note:
Ensure that zebra contacts sit nicely in place and that the microphone is attached to the keypad holder.
Also, make sure that zebra and microphone contacts are not corroded.
PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
COMPANY RESTRICTED
VY-V-640-82x
Page : 60 of 71
Langue : EN
Date : 25/02/03
Check that zebra contacts and
microphone are in place
VY-V-640-82x