Philips Fisio 820 Service Manual page 42

Cellular telephone
Hide thumbs Also See for Fisio 820:
Table of Contents

Advertisement

Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
b) Check Current_ON
- Turn the mobile on.
When the mobile is ON (backlight activated)
For Fisio 820 :
the current measured must be : 150 < I (mA) < 190
For Fisio 825 :
the current measured must be : 200 < I (mA) < 240
This measurement has to be operated during first seconds after switch on.
When the backlight goes down
models
c) Check Current_maximum
- Press on OK to activate Page selection. Press the Key 1 and then OK to select Page 1
- Press on Key 7 to select Antenna test. Press on the Key 8 as much times as necessary to reach level 5.
mobile is now set at his maximum emission level)
When the mobile is emitting (backlight OFF) the current measured must be :
- Remove the battery.
- Gently slide the card out away from the Product
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
, the current measured must be : 15 < I (mA) < 19
(after 15 sec approx.)
COMPANY RESTRICTED
VY-V-640-82x
Page : 42 of 71
Langue : EN
Date : 25/02/03
195 < I (mA) < 350
VY-V-640-82x
for both
(The

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fisio 825

Table of Contents