Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
7.10.3 Bluetooth air interface parameters
Keys parameters
Frequency Band
Channel Spacing
RF bandwidth
Number of Channels
Modulation
Communication method: TDD
Frequency Hopping
Peak data rate
Maximum output power : 100mW (20dBm)
Sensitivity
Frequency Band and RF Channels
Power Classes
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
: 2.4GHz ISM Open band
: 1MHz
: 220kHz(-3dB), 1MHz(-20dBm)
: 79 or 23
(Depend on the country arrangement )
: GFSK
: 1600 hops/s (625 msec)
: <1Mbit/sec
(Depend on power class)
: -70 dBm @ BER=1/1000
Country
Country
Frequency Range
Frequency Range
Europe & USA
2400 - 2483.5MHz
Japan
2471 - 2497MHz
Spain
2445 - 2475MHz
France
2446.5 -2483.5MHz
Power
Maximum
Nominal
Power
Maximum
Nominal
Class
Class
Output Power
Output Power
Output Power
Output Power
100 mW (20 dBm)
N/A
1
2.5 mW (4 dBm)
1mW (0 dBm)
2
1 mW (0 dBm)
N/A
3
Note 1: Minimum output power at maximum power setting.
Note 2: The lower range limit of -30 dBm is not mandatory and may be chosen
according to application needs.
COMPANY RESTRICTED
RF Channels
RF Channels
k = 0 to 78
F=2402 + k MHz
k = 0 to 22
F=2473 + k MHz
F=2449 + k MHz
k = 0 to 22
F=2454 + k MHz
k = 0 to 22
Minimum
Minimum
Power Control
Power Control
1)
Output Power
Output Power
1)
1 mW (0 dBm)
4 to +20 dBm
2)
-30
to 0 dBm,
optional
2)
0.25 mW (-6 dBm)
-30
to 0 dBm,
optional
2)
N/A
-30
to 0 dBm,
optional
VY-V-640-82x