Installing Amplifiers

CAUTION
Before attempting to install or remove a signal condi-
tioner, turn off the power at the GX-1 main unit. If you
attempt installation or removal while the power is
turned on, you might damage the GX-1 main unit and
the signal conditioner.
Channel Numbers
Slots are numbered from the left (as viewed from the front
of the GX-1 main unit) in the order 1, 2, 3, etc. These corre-
spond to channels 1 and 2, channels 3 and 4, etc. The input
terminal A of each signal conditioner corresponds to the
smaller number of the channel numbers, and input terminal
B corresponds to the next channel. For example, A of slot 3
is channel 5.
Installation Procedure
1.
Loosen the two screws at the top and bottom of the blank
panel, and remove the panel.
(You cannot remove the screws from the panel even after
you loosen them.)
2.
Insert the signal conditioner into the slot. Insert the lower
edge of the board into the guide rail.
Holding the signal conditioner vertically, press it in firmly.
3.
Tighten the two screws at the top and bottom.
This completes the installation.
Set the parameters
The parameter settings for the GX-1 main unit are reset
when you add a new signal conditioner or move a signal
conditioner to another slot. So choose Setup and then
Params to revise the settings for all channels.
Attaching Ferrite Core
The cable connected to the input connector may emit radio
noise. To reduce the radio noise, attach the supplied ferrite
core on the input cable.
Open the ferrite core, turn the cable around the ferrite core, and
close the core. (See fig. 1.)
Note: If the cable is thick, just pass the cable through the ferrite
core and secure the core with the cable tie. (See fig. 2.)
within